Vacuum equipment sales and vacuum pump
rebuilding services for high vacuum
pumps used in mass spectrometers,
vacuum chambers
semiconductor processes ,
medical devices ...

Vacuum Pump Service:

  • Links

  • Contact:

    SALE VACUUM PUMPS

    Vacuum pumps sales and service.
    Call 408-607-4135

    Vacuum Pumps SALES



    VACUUM PUMPS ON SALE :

    Vacuum Pump Service:


    • High Vacuum Pumps

    • Turbomolecular Vacuum Pumps

    • Scrool Vacuum Pumps

    • Ebara Vacuum Pumps

    • Air Cooled Vacuum Pumps

    • Water Cooled Vacuum Pumps

    • Dry Vacuum Pumps

    • Diffusion Vacuum Pumps

    • Cryo Pumps

    • Leybold Vacuum Pumps

    • Boc Edwards Vacuum Pumps

    • Varian Vacuum Pumps

    • Adixen Vacuum Pumps

    • Pfeiffer Vacuum Pumps

    • Seiko Seiki Turbo Vacuum Pumps


    • Leybold Vacuum Pumps and Blower Package.Trivac,Ruvac,Sogevac


      - Leybold TRIVAC vacuum pumps:

      D1.6B, D4B, S8B, D8B, S16B, D16B, D16BCS Leybold S25B,D25B/BCS,S40B, D40B/BCS,D65B/BCS
      Leybold D2A, D2AC, D4A, D4AC, D8A, D8AC, D16A, D16AC - Leybold S30A,D30A,D30AC,S60A,D60A ,D60AC,S90A,D90A,D90AC

      - Leybold Sogevac Vacuum Pumps:

      Leybold SV10B,SV16B,SV25B, SV40B,SV65B,SV100B Leybold SV16, SV25, SV40, SV65, SV100, SV180, SV200 Leybold SV280,SV300,SV500, SV585,SV630,SV630F,SV750 Leybold D1.2E, D2.5E, D5E, D10E, D16E Leybold S100C/F, S160C/F, S250C/F, S400F/FL, S630F/FL

      - Leybold Rotary Piston Pumps:

      E75, E150, E250, DK100, DK200 Leybold SC15D,SC30D

      - Leybold RUVAC Blowers:

      Leybold WA & WAU 150,151,250, 251,500,501,1000,1001,2000,2001 Leybold WS & WSU 150,151,250, 251,500,501,1000,1001,2000,2001

      Leybold RA3001 & S, RA5001 & S,RA7001 & S,RA9001 Leybold 25B, 50B, 100B, 25P, 50P, 100P, 25S, 50S, 100S

      Edwards Vacuum pumps

      RV Edwards vacuum pumps:

      RV3 Vacuum pump RV5 Vacuum pump RV8 Vacuum pump RV12 Vacuum pump

      Small Edwards EM series pumps:

      Edwards e2m2 Edwards e1m5 Edwards e2m5 Edwards e1m8 Edwards e2m8 Edwards e2m12 Edwards e1m18 Edwards e2m18 Edwards e2m28 Edwards e2m30

      Medium Edwards EM pumps:

      Edwards e1m40 Edwards e2m40 Edwards e1m80 Edwards e2m80
      Large Edwards EM pumps:

      Edwards e1m175 Edwards e2m175 Edwards e1m275 Edwards e2m275

      Edwards 3000 vacuum pump Edwards 1900 vacuum pump Edwards GV400 vacuum pump Edwards Blowers (Rootes pumps) Full parts and spares list Edwards Blowers (Rootes pumps): Edwards e2m2 vacuum pump Edwards e1m5 vacuum pump Edwards e2m5 vacuum pump Edwards e1m8 vacuum pump Edwards e2m8 vacuum pump Edwards e2m12 vacuum pump Edwards e1m18 vacuum pump Edwards e2m18 vacuum pump Edwards e2m28 vacuum pump Edwards e2m30 vacuum pump Edwards e1m40 vacuum pump Edwards e2m40 vacuum pump Edwards e1m80 vacuum pump Edwards e2m80 vacuum pump Edwards e1m175 vacuum pump Edwards e2m175 vacuum pump Edwards e1m275 vacuum pump Edwards e2m275 vacuum pump EH250 blower EH500A blower EH1200 blower EH2600 blower EH4200 blower Edwards Turbo pumps
    High vacuum pumps models:Anest Iwata ISP Series ISP250B, ISP500B DVSL Series DVSL100B, DVSL500B BOC Edwards XDS Series XDS5/5C, XDS10/10C, XDS35i ESDP Series ESDP12-30 GVSP Series XDD1 Varian SH100, PTS0300X, PTS0600X CRYO PUMPS: CTI Cryogenics Compressors SC, SCW, 8200, 8510 Cryo-Torr 8F, 250F, 8, 10, 350CP On-Board 8, 10, 8F, 250F, 10F, 400 DRY PUMPS: BOC Edwards QDP Series QDP80, QDP40/QMB250, QDP80/QMB250, QDP80/QMB500 iQDP Series iQDP40, iQDP80, iQDP40/QMB250, iQDP80/QMB250, iQDP80/QMB500 Ebara UERR Series UERR 40X20, UERR 64X40, UERR 50X20, UERR 80X25, UERR 150X40 A Series A07V 80X25, A10S, A25S, A30W, A70W, A150W AA Series AA10, AA20, AA40W, AA70W, AA100W, AA200W AAS Series AAS10, AAS20, AAS70, AAS100, AAS200, AAS300 ESR Series ESR 20N, ESR 80WN, ESR 200WN PISTON PUMPS: Leybold E Series E75, E150, E250 DK Series DK50, DK250 Kinneys KD Series KD-30, KD-50, KDH-130 KT Series KT-170LP, KT-150, KT-300, KT-500, KT-850 KC Series KC-5, KC-8, KC-15 KTC Series KTC-21, KTC-60, KTC-112 Stokes 146, 146H11, 148-10, 148H11, 149H11, 212H11, 412H10, 412H11 TURBO PUMPS: Alcatel Alcatelturbo pumps: 5010, 5080, 5150, 5150CP Leybold TURBOVAC Series 50, 151, 151C, 361, 361C, 600C, 1100C, T1600, TW 70H w/ Frequency Converter, TW 70H w/o Frequency Converter, TW 300 w/ Frequency Converter, TW 300H w/o Frequency Converter, TW 300H w/ Frequency Converter, TW 701, TW 1600, 340M, TMV40000, BMH70 MAG Series 400C, 400CT, 1500CT, 2000C/CT, W830, W830C, W1300, W1300C, W1500CT, W2000C/CT, W1500CT, W2000C/CT, W2200C, W2200C, W2800C PT Series 50, 151, 361, 50KIT, 151KIT water-cooled, 361 water-cooled, 300, 301, TOSS50, MINI-TOPS50, TOPS151, TOPS361 Alcatel Single Stage 1004A, 1012A, 1030, 1033, 1060, 1063 Dual Stage 2004, 2004A, 2007, 2008AC, 2012AC, 2021AC, 2030C, 2033C, 2060C, 2063C, 2100AC BOC Edwards SP Series SP2 EM Series E1M5, E1M8, E1M12, E1M18, E1M30, E1M40, E1M80, E1M175, E1M275, E2M0.7, E2M1, E2M1.5, E2M2, E2M5, E2M8, E2M12, E2M18, E2M28, E2M30, E2M40, E2M80, E2M175, E2M275, E-Lab2 RV Series RV3, RV5, RV8, RV12 Stokes U017-2, U023-2 Busch R5 Series R5-0006, R5-0010, R5-0012, R5-0016, R5-0021, R5-0025, R5-0040, R5-0065, R5-0100, R5-0160, R5-0250, R5-0400, R5-0630, R5-1000, R5-1600 Leybold RUVAC Series RA 3001 (50Hz), RA 5001 (50Hz), RA 7001 (50Hz), RA 9001 (50Hz), RA 13000 (50Hz), RA 3001 (60Hz), RA 5001 (60Hz), RA 7001 (60Hz), RA 9001 (60Hz) SOGEVAC Series SV 10B, SV 16B, SV 25B, SV 40B, SV 65B, SV 100B, SV 16, SV 25, SV 200, SV 300, SV 500, SV 630, SV 630F, SV 750, SV 1200 TRIVAC Series D2A, D4A, D8A, D16A, D30A, D60A, D1.6B, D4B, D8B, D16B, D25B, D40B, D65B, D16BCS, D25BCS, D40BCS, S40BCS, S65BCS, D65BCS SARGENT WELCH All Series 1374, 1375, 1376, 1397, 1398, 1400, 1405, 1373, 1380, 1399, 1403, 1404, 1410 Alcatel RHV Series RHV250, RHV500, RHV1000 BOC Edwards EH Series EH250, EH500, EH1200, EH2600, EH4200 QMB Series QMB-250, QMB500, QMB1200 Leybold WA Series WA150, WA151, WA250, WA251, WA501, WA1001, WA2001 WAU Series WAU250, WAU251, WAU501, WAU1001, WAU2001 WS Series WS251, WS500, WS501, WS2001, WS2001FC,WSLF 1001 WSU Series WSU251, WSU501, WSU1001, WSU2001 RA Series Stokes Blowers 607-1, 607-2, 607-401, 607-402, 607-403, 615-1, 615-2, 615-401, 615-402, 622-1, 622-2, 622-3, 306-401, 310-41, 615, 306H11 TURBO PUMP REPAIR,Pump:Turbo:Vacuum Pump sales,Vacuum Pumps for sale.Turbo pump sales,Turbo pump Service,Vacuum pump Service,VACUUM,VACUUM PUMP REPAIR,TURBO PUMP SALES,TURBO PUMP,SERVICE,VACUUM PUMP SERVICE,VACUUM PUMP SALES,Turbo pump sales & service. ,turbo,ion,cryo,diffusion,mechanical,Leybold vacuum,Pfeiffer vacuum,Seiko Seiki STPH-1000C,Seiko Seiki STPA-2203P1,Seiko Seiki STPH-1301,Seiko Seiki STP-400, Seiko Seiki STP-A2503PV,Seiko Seiki STP-H2002C,Seiko Seiki STP-H2000C,Seiko Seiki STP-A1603C,turbopump, TURBO PUMP REPAIR(turbo,ion,cryo,diffusion,frequency converters),High Vacuum Pumps,Leak Detectors and vacuum equipment for the semiconductor and high vacuum related industries.Turbo pump sales,Turbo pump service,Turbo pump repair,Turbo pump rebuilding services,Vacuum pump sales & Service. VACUUM/High vacuum,Vacuum pump, TURBO PUMP REPAIR.Repair and service high vacuum equipment

    turbo pumps
    Ultra high vacuum (UHV) is the vacuum regime characterised by pressures lower than about 10-7 pascal or 100 nanopascals (10-9 mbar, ~10-9 torr). UHV requires the use of special materials in creating the vacuum system, extreme cleanliness to maintain the vacuum system, and baking of the entire system to remove water and other trace gases that adsorb on the surfaces of the chamber. At these low pressures the mean free path of a gas molecule is approximately 40 km, so gas molecules will collide with the chamber walls many times before colliding with each other. Almost all interactions therefore take place on various surfaces in the chamber.

    High vacuum - vacuum chambers - ultra high pumps for mass spectrometers.

    Vacuum Pump Sales.
    Vacuum is an integral part of many laboratory processes, but costs associated with generating a vacuum, such as process costs, user costs and cost to the environment, have never really been considered seriously. Although technology has advanced to provide smaller, cleaner and quieter options, not many people are taking advantage of it. Vacuum pumps last a long time and many people go through their careers without actually buying one. Hence, people tend to replace their vacuum pumps with what they have used before and not take the time to find out about the alternatives.

    Vacuum pumps used in laboratories can be classified into two main types rotary vane pumps, sometimes referred to as oillubricated pumps, and dry (oil-free) pumps. They operate in different ways to create vacuum and aspirate fluids. Centrifugal pumps use centrifugal force to push the fluid through an outlet; metering pumps, such as diaphragm, peristaltic, piston and syringe pumps, pull fluid into a chamber and then push it through the outlet valve; while positive displacement pumps use bellows, piston, rotary lobe and rotary vane to push fluid through a cavity, leaving a vacuum that pulls in more fluid.

    Oil-lubricated pumps have been around for many decades, while the oil-free diaphragm pumps are a more recent addition. Although oil-free pumps tend to be one and a half to two times more expensive than oil pumps, there are a lot of advantages to their use as well as significant lifetime savings. First of all, no oil is used, and therefore there is no cause for oil contamination and no necessity for oil change or disposal. Oil-free pumps can be built to be corrosion resistant and hence do not require regular maintenance. Service intervals on better oil-free pumps exceed 10,000 operating hours. If you use your vacuum pump 20 hours a week, 50 weeks a year, that's 10 years before the first scheduled service!

    The other misunderstanding that leads to the choice of an oillubricated pump is that people think that more vacuum is always better. Oil-free diaphragm vacuum pumps can provide vacuum levels from atmosphere to below 0.5 mbar/torr, whereas oil-lubricated pumps offer high capacities and higher vacuum levels up to 10-3 mbar/torr. What is more important is matching the vacuum to the application, and almost any application can now be performed using an oil-free pump, with the exception of freezedrying.

    For certain applications he also recommends considering buying a pump with controls that provide a good balance of speed and control. Even manual controls are better than none, but electronic controls offer huge productivity advantages, he says. In many applications, the type of vacuum control used will determine how much scientist time is needed for oversight and how fast the application proceeds.

    It is often very helpful to talk to someone from a vacuum pump company, who can recommend a pump and offer a demonstration about what will be right for your application and budget. There are also interactive online vacuum pump selection guides available that ask a few questions about the planned use for the pump and recommend a series of pumps to satisfy a range of budgets. It is not a glamorous technology but it is one that can affect the costs, comfort and convenience of your laboratory.

    Sale Vacuum Pumps, Vacuum Pumps for sale, used Vacuum Pumps, surplus Vacuum Pumps,adixen vacuum pumps,alcatel vacuum pumps,leybold vacuum pumps,oerlikon vacuum pumps,boc edwards vacuum pumps,kinney vacuum pumps,pfeiffer vacuum pumps, welch vacuum pumps,Sale adixen vacuum pumps,Sale alcatel vacuum pumps,Sale leybold vacuum pumps,Sale oerlikon vacuum pumps,Sale boc edwards vacuum pumps,Sale kinney vacuum pumps,Sale pfeiffer vacuum pumps,Sale welch vacuum pumps Vacuum pumps and solutions:OIL FREE VACUUM PUMPS:Dry Scroll Pumps: Refurbished Scroll Pumps from Anest Iwata, BOC Edwards and Varian: Anest Iwata ISP Series ISP250B, ISP500B DVSL Series DVSL100B, DVSL500B BOC Edwards XDS Series XDS5/5C, XDS10/10C, XDS35i ESDP Series ESDP12-30 GVSP Series XDD1 Varian SH100, PTS0300X, PTS0600X

    Service & Repair of turbo vacuum pumps and controllers including:Bearing changes, Regreasing, Cleaning, Repair and Balancing.

    Vacuum Pump Sales & Service for Alcatel Adixen,Pfeiffer,Balzers,Oerlikon Leybold,Varian,Rigaku,Boc Edwards,Seiko Seiki,Balzers.

    Standard major repair includes complete disassembly,decontamination,chemical clean, inspection of all components,bake out all parts prior to assembly,install major kit (bearings,hardware,seals),leak check,dynamic balancing and integrity test for 24 hours to insure operational specifications are met.Any damage to the rotor,discs,shaft,motor or other major parts not covered inthe major rebuild will need customer approval before work is done.

    - We combine state of the art balancing and FFT diagnostic equipment, 25 years in repairing machinery, and 15 years of applied high vacuum techniques to ensure proper repair of your turbomolecular pump.

    - Highest quality replacement parts, such as permanently lubricated ceramic bearings, are used in all repairs.

    - Most repairs are completed within 15 days. Emergency repair service with a 3-5 day turnaround is available.

    - Repairs are competitively priced. Discounts for universities are available.

    A pump which removes gas molecules from an enclosed volume so that a partial vacuum is left behind is known as a vacuum pump. It was invented by Otto von Guericke in 1650. Pumps can be classified into three types according to the technology used. These three types are the Positive displacement pump, Momentum transfer pump and the Entrapment pump.

    Momentum Transfer Pumps, which are also known as molecular pumps, use high speed jets of thick fluid or high speed rotating blades to propel the molecules in gaseous state out of the chamber. Entrapment pumps trap gases in a solid state. Positive displacement pumps are most efficient for vacuums that are low.

    The kinetic pumps apply momentum to the gas so that mechanics of the moving parts of the machine make the gas transfer from the inlet area to the outlet area of the pump. When the moving part is in motion, the gas molecules are accelerated and moves towards the area where there is low pressure.

    When this process is continuously repeated, the molecules are pushed out from the container. This is done to create vacuum. When the required vacuum level is reached at, the tank is isolated using a high vacuum valve. This dis-allows the gases between container and pump to exchange.

    A large variety of vacuum pumps are combined with chambers or containers of different types and using different procedures resulting into a very wide range of vacuum pumps. A positive displacement pump can be used to create a partial vacuum by transferring gas molecules from the container to outlet. But this may not be the perfect kind of vacuum created. Other techniques can be used to achieve such a vacuum. The combination of chamber and procedure to create a vacuum will depend on what type of f vacuum needs to be created.

    It is extremely difficult to achieve the perfect vacuum. Sometimes more than one pump type is used for a single operation. The combinations of pump types used depends upon the quality of vacuum desired. In spite of a lot of advancement pump technology has its limitations. Therefore the quality of the vacuum achieved is fairly crude. Quality can be improved by subjecting the container to a process of extreme drying. This should be done before vacuum pumping it.

    Extremely high vacuums can be generated through custom built equipment made of stainless steel. A vacuum pump can be available in wide varieties and forms. The utility of such pumps is extremely high.

    Turbomolecular vacuum pump repair, sales and service.

    Turbo vacuum pumps we repair:

    Alcatel: 5080, 5100, 5150, 5400, 5900 ATP series:ATP 80,ATP 100,ATP 150,ATP 400,ATP 900 MDP series:MDP 5010,MDP 5011,MDP 5030

    Balzers/Pfeiffer: TPH/U:TPH/U 040,TPH/U 050,TPH/U 060,TPH/U 062,TPH/U 100,TPH/U 110,TPH/U 170,TPH/U 180H,TPH/U 190,TPH/U 200,TPH/U 240,TPH/U 260,TPH/U 270,TPH/U 330,TPH/U 510,TPH/U 2200 TMU/H:TPH/U 064,TPH/U 065,TPH/U 071,TPH/U 261,TPH/U 521

    Edwards: EXT70, EXT 250, EXT 351, EXT 501, EXT 501E

    Leybold: Turbovac/TMP 50, TMP 150,TMP 151,TMP 360,TMP 361,TMP 450,TMP 1000,TMP 1500

    Rigaku: RTPG 150, RTP 300

    Varian: Elettrorava V80, V80A, V200, V200A, V300, V450, V1000, V1000A, MacroTorr series: V70, V250, V300HT, V550, V551, V700, V1000HT, SCIEX V801

    We are looking for the following vacuum pumps;



    Leybold TMP 361C & TMP 1000C ,Pfeiffer: TMH-1600 PC, TPH-1600C, TMH/U-1000/1001, TMH/U-520, TMH/U-521 TMH-261, TMH-071, TPH-060, TPH/U 510 TCP-380, TC-600 Controllers

    -Varian: V-1000 ICE, V-1000A, V-550, V-551, V-70 LP. Varian Turbo Controllers

    -Seiko Seiki: STP-600C, STP-1000C, STP-H1000C, STP-301C, STP-300C, STP-A1303C. SCU-301, SCU 21D Controllers

    -Alcatel: ATP-80, ATP-150, ATP-400. ACT-600, ATP-900 HPC, ACT-1000 Controllers RSV-601B Blower, 2021 Vane pump.

    -Leybold:Tmp 361c,TMP 1000 ,Mag 400 Turbo, NT-20 Controllers E-250 WA-251, WA-501, WA-2000 or WA-2001, Sogevac: SV-100, SV-200, SV-300

    -Edwards EXT-70, 70H, 250, 250H, 255H Turbos E2M275 Vane Pump

    -Turbo Pumps: any good deals on surplus turbo pumps or controllers. Vane Pumps: any 3-20 CFM Pumps with 115 volt, single phase motors

    -Stokes V-017, V-023 Vane Pumps. 310, 615 Blowers

    -CTI: 9600, 8200, 8500, 8510 Compressors, CT-8F OB Conflat, three phase motor controllers

    -Leak Detectors: Alcatel ASM-180T, ASM-180 TD+, Varian 959 or 979 (or any non DP leak detector)

    -Busch RC-40, 63, 160, 250

    VACUUM PUMP BUYERS If you have any of the above, please email back the condition, availability and price.

    Oerlikon Leybold

    Most Oerlikon Leybold Turbovac TMP models produce a clean, hydrocarbon free vacuum at an ultimate pressure of <10-10 mbar. Other features of the TMP models include grease lubricated bearings that permit the pump to operate in any desired angular position, while retaining the advantages of single axial flow construction; dynamic balancing of the pump's replaceable rotor/spindle assembly produces silent running with minimal vibration; the turbine and drive assembly with internal motor are mounted in a stainless steel housing; the pump motor is protected from overheating by a thermal switch, which turns off the pump's frequency converter if the pump motor exceeds its safe operating temperature limit; a heat treated aluminum alloy is used for the rotor assembly; the complete drive assembly including bearings and motor is located in the fore vacuum space.For use in:Helium leak detectors, Mass spectrometers,liquid chromatography,residual gas analysis,mobile analytical systems,Electron beam microscopy,XHV-/UHV systems,Transfer chambers, Semiconductor Technology, Analytical and Medical Technology, Coating, Research and Development, Industrial Applications, Products and Applications

    Turbomolecular vacuum pump repair, sales and service.

    Turbo vacuum pumps we repair:

    Alcatel: 5080, 5100, 5150, 5400, 5900 ATP series:ATP 80,ATP 100,ATP 150,ATP 400,ATP 900 MDP series:MDP 5010,MDP 5011,MDP 5030

    Balzers/Pfeiffer: TPH/U:TPH/U 040,TPH/U 050,TPH/U 060,TPH/U 062,TPH/U 100,TPH/U 110,TPH/U 170,TPH/U 180H,TPH/U 190,TPH/U 200,TPH/U 240,TPH/U 260,TPH/U 270,TPH/U 330,TPH/U 510,TPH/U 2200 TMU/H:TPH/U 064,TPH/U 065,TPH/U 071,TPH/U 261,TPH/U 521

    Edwards: EXT70, EXT 250, EXT 351, EXT 501, EXT 501E

    Leybold: Turbovac/TMP 50, TMP 150,TMP 151,TMP 360,TMP 361,TMP 450,TMP 1000,TMP 1500

    Rigaku: RTPG 150, RTP 300

    Varian: Elettrorava V80, V80A, V200, V200A, V300, V450, V1000, V1000A, MacroTorr series: V70, V250, V300HT, V550, V551, V700, V1000HT, SCIEX V801

    SALE VACUUM PUMPS